Wuxi Highness Technology Co., Ltd

Company News >> water decoloring agent HNS-08 Application technical information
 The dyehouses are divided in 2 categories:

 
A. When they have biological treatment first and after they make chemical treatment. In this case they use:
 
      70-80 ppm HNS-08
      15-20 ppm Polyaluminum Chloride
      1-2  ppm Anionic polyacrylamide
 
First we apply the PAC (contact time 3-5 min with the waste water), after then HNS-08 Water Decoloring Agent (contact time 5-10 min), and after then anionic polyacrylamide.
 
It will give too much economy if we'll adjust the pH 7-8, otherwise the consumption of HNS-08 will be ~20% higher.
 
B. When the treat first by chemicals, then the usual dosages are :
       Adjustment the pH 7-8
       80-100 ppm HNS-08
       10-20 ppm  PAC
       1-2  ppm  Anionic polyacrylamide